Radnoti Four Channel Blood Vessel Perfusion System
Toll Free 1-800-428-1416 227 West Maple Ave Monrovia, Ca 91016 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Radnoti Vessel Perfusion
158700-1
158700-4
|
Radnoti Blood Vessel Perfusion System Measurements of isolated blood vessel contractility can be made on ring segments using isometric (or Isotonic) force transducers. Contractility measurements can also be made on blood vessel sections that have been cannulated and then are perfused at either a constant pressure or a constant flow. Radnoti has constructed a four-bath system that permits this type of measurement to be made conveniently. The vessel section is cannulated with one of a set of cannulae and placed in a water-jacketed bath that can be aerated. In the constant pressure mode, a reservoir (or bubble trap) is placed above the bath at a given hydrostatic head and flow is changed by the contraction or dilation of the vessel. Flow measurements are made using drop counters, flow meters or other devices. In the constant flow mode, a peristaltic or syringe pump delivers fluid at a predetermined rate. In-line pressure transducers measure changes in diameter via changes in pressure. In the constant flow system, drugs may be infused into the system via syringe pumps. In both modes, the media outside the vessels can be changed independently of the media perfused through the vessels. It is also possible to directly measure the diameter of the vessel using a camera. Note that in certain cases an aquarium pump can be used to aerate tissues with low oxygen requirements in non-bicarbonate buffer systems, thereby eliminating the problems and expense of gas tanks and regulators. Instrumentation includes 4 pressure transducers, a peristaltic pump, reservoirs, bubble traps, recirculating bath, and all associated tubing and connectors. Available options: Indwelling electrodes for tissue stimulation, a tissue stimulator, flowmeters, or other fluid measuring devices, camera, air pump, and data acquisition with automation.
![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
![]() |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||