Products

Stimulators

Grass Stimulator S88X

Request Quotation


Grass Technolgy S88X Dual Output Square Pulse Stimulator

The S88X is a dual output, general purpose stimulator for nerve and muscle stimulation procedures.
This new stimulator has touch-pad controls.

Applications extend from single cell to entire muscle stimulation. The two output channels can be operated independently or synchronized to produce complex paradigms. The outputs are non-isolated constant voltage monophasic, biphasic or twin pulses. Up to 9 sets of parameters can be saved for future use.

New features include:
• Digital controls – precise timing accuracy
• Bright display simplifies setup
• Independent or synchronous channel operation
• Monophasic and biphasic modes
• Dual train output
• High current output facilitates field stimulation
• New companion isolation units
• Software replacement via USB cable


Train Rate (S1 and S2):
1/100 sec to 99 TPS
Train Duration: 1 msec to 99 sec
Rate (S1 and S2): 1/100 sec to 1000 PPS
Pulse Delay (S1 and S2): 10 µsec to 99 sec
Pulse Duration (S1 and S2): 10 µsec to 99 sec
Synchronous Outputs (TTL): S1, S2, S1 Delay, S2 Delay, Train; Front panel BNC connectors, 50 ohm, 10 µsec pulses, can source/sink 20 mA peak.
Synchronous Inputs (TTL): Train Duration, S1 Delay, S2 Delay; Front panel BNC connectors, 4.75 kohm pullup to 5 volts
Stimulus Output: 250 mV to 24 VDC (monophasic) ±250 mV to ±12 VDC (biphasic)
Peak Output Current: 1 A
Output Protection: Yes, current limited
Output Impedance: <2 ohms
Maximum Power Out: 24 W peak
AC Power: 115/230 volts, 50/60 Hz, 100 watts maximum
Physical Size: 19" W x 5.25" H x 12.5" D (48.3 cm x 13.4 cm x 31.8 cm)
Weight: 10 lbs. (4.5 kg)
Regulatory Safety: EN 61010-1:2001, UL 61010A-1, CSA C22.2 No. 1010.1-92. EMC: FCC Part 15, Subpart B, Class B, EN 61326:1998 Class B

 

Grass Technolgy S88 Dual Output Square Pulse Stimulator

The S88 is a dual output, general purpose stimulator for nerve and muscle stimulation procedures. Applications extend from single cell to entire muscle stimulation. The two output channels can be operated independently or synchronized to produce complex paradigms. The outputs are non-isolated constant voltage positive pulses. New features include computer compatibility and flexibility of synchronization circuits. The synchronous inputs and outputs are TTL, 5 volt, PC compatible. A rear DB25S connector permits external analog control of the timing circuits. Optional Stimulus Isolation Units are available for applications requiring isolation and/or constant current.

Train Rate (S1 and S2): 1/100 sec to 100 TPS (4 decades)
Train Duration: 1 msec to 10 sec (4 decades)
Rate (S1 and S2): 1/100 sec to 1000 PPS
Pulse Delay (S1 and S2): 10 µsec to 10 sec (6 decades)
Pulse Duration (S1 and S2): 10 µsec to 10 sec (6 decades)
Synchronous Outputs (TTL): S1, S2, S1 Delay, S2 Delay, Train; Front panel: 10 µsec ,50 ohm, 10 µsec pulses. Rear Panel: 1 or 10 msec and Train end
Synchronous Inputs (TTL): Train Duration, S1 Delay, S2 Delay; Trigger from rising or falling edge
Rear Connector (DB25S): All SYNC INPUTS and OUTPUTS; External Analog Rate Control

Volts Out (S1 and S2): 10mV to 150V (4 decades)
Peak Output Current: 450 mA
Output Impedance: 250 ohm nominal on all voltage ranges; 25 ohm and 100 kohm on highest range
AC Power: 115/230 volts, 50/60 Hz, 125 watts peak, 20 watts standby
Physical Size: 19" W x 5.25" H x 12.5" D (48.3 cm x 13.4 cm x 31.8 cm)

Rackmount: Optional S88RK: 19" (48.3 cm) Rackmount brackets
Weight: 17 lbs. 10 ozs. (7.9 kg)
Regulatory: Safety: UL 3101-1, CSA C22.2 No. 1010-1, EN 610101; Other European Standards: EN 55011, EN 500821 European Directives: 73/23/EEX, 89/336/EEC